QB Electrical
Type: Fused disconnect (compatible with Class R, T, or H fuses)
Voltage: 240V AC max
Current Rating: 30A–60A (based on wire lugs & design)
HP Rating: Horsepower-rated (exact HP depends on model, e.g., 5–15 hp)
Fault Current:
100,000 AIC (with Class R/T fuses)
10,000 AIC (with Class H fuses)
Switching Mechanism: Visible blade, double-break
Enclosure: NEMA 3R (indoor/outdoor)
Terminals: Oversized lugs (easier wire termination)
Safety: Padlockable (cover & handle)
Material: Steel
Dimensions: Compact design (exact size varies by amp rating)
✔ Fused protection for motors, HVAC, and industrial equipment
✔ Applications needing fault current protection (up to 100kA with Class R/T fuses)
✔ General-duty environments (not for severe conditions)
Type: Non-fused disconnect (no fuses, acts as a manual isolator)
Voltage: 240V AC / 250V DC
Current Rating: 60A
HP Rating:
10 hp (1-phase)
15 hp (3-phase)
Short Circuit Rating: 10kA (1-phase) / 100kA (3-phase)
Poles: 2-pole (DPST)
Switching Mechanism: Double-break, visible blade
Enclosure: NEMA 3R (weather-resistant)
Terminals: Line/Load/Neutral lugs (supports 3-wire setups)
Safety: Padlockable actuator
Material: Galvanized steel (gray finish)
Dimensions: 8.56" H × 5.44" W × 2.75" D
✔ Motor disconnects (no fuse replacement needed)
SS-OD-2P-60A-F GF222NRA
QB Electrical
2P 60A Rainproof GF222NRA/GNF222RASS-OD-2P-60A-F GF222NRA
Type: Fused disconnect (compatible with Class R, T, or H fuses)
Voltage: 240V AC max
Current Rating: 30A–60A (based on wire lugs & design)
HP Rating: Horsepower-rated (exact HP depends on model, e.g., 5–15 hp)
Fault Current:
100,000 AIC (with Class R/T fuses)
10,000 AIC (with Class H fuses)
Switching Mechanism: Visible blade, double-break
Enclosure: NEMA 3R (indoor/outdoor)
Terminals: Oversized lugs (easier wire termination)
Safety: Padlockable (cover & handle)
Material: Steel
Dimensions: Compact design (exact size varies by amp rating)
✔ Fused protection for motors, HVAC, and industrial equipment
✔ Applications needing fault current protection (up to 100kA with Class R/T fuses)
✔ General-duty environments (not for severe conditions)
Type: Non-fused disconnect (no fuses, acts as a manual isolator)
Voltage: 240V AC / 250V DC
Current Rating: 60A
HP Rating:
10 hp (1-phase)
15 hp (3-phase)
Short Circuit Rating: 10kA (1-phase) / 100kA (3-phase)
Poles: 2-pole (DPST)
Switching Mechanism: Double-break, visible blade
Enclosure: NEMA 3R (weather-resistant)
Terminals: Line/Load/Neutral lugs (supports 3-wire setups)
Safety: Padlockable actuator
Material: Galvanized steel (gray finish)
Dimensions: 8.56" H × 5.44" W × 2.75" D
✔ Motor disconnects (no fuse replacement needed)
Price |
---|
Vendor |
SKU |
Short Description |
Weight |
Stock |