Feature | HF364N (Fused + Neutral) | HNF364 (Non-Fused) | HF364 (Fused, 3-Wire) |
---|---|---|---|
Type | 3P + solid neutral fused | 3P non-fused | 3P fused (no neutral) |
Current/Voltage | 200A, 600V AC | 200A, 600V AC | 200A, 600V AC |
Fuse Support | Class J/R/T (3 fuses) | None | Class J/R/T (3 fuses) |
Wiring | 3P + neutral (4-wire) | 3P (3-wire) | 3P (3-wire) |
Short-Circuit Protection | 200kA (Class R/J) | Requires external OCPD | 200kA (Class R/J) |
Enclosure | NEMA Type 1 (indoor) | NEMA Type 1 (indoor) | NEMA Type 1 (indoor) |
Mechanism | Quick-make/break, visible blade | Quick-make/break, visible blade | Quick-make/break, visible blade |
Padlocking | Yes | Yes | Yes |
UL Service Entrance | Yes | No (disconnect only) | Yes |
Typical Use | 3-phase systems needing neutral | Motor disconnects | 3-phase circuits without neutral |
Neutral Presence
HF364N: Only model with a solid neutral (for 4-wire systems).
HNF364/HF364: 3-wire only (no neutral).
Fused vs. Non-Fused
HF364N & HF364: Include fuse protection (200kA fault rating with Class R/J).
HNF364: Disconnect-only (relies on upstream breakers/fuses).
Applications
HF364N: Service entrances, 3-phase + neutral loads (e.g., HVAC, industrial panels).
HF364: 3-phase circuits without neutral (e.g., motors, pumps).
HNF364: Simple isolation (maintenance, motor disconnects).
SS-ID-600V-200A- HF364
QB Electrical
200 Amp. 3P Heavy Duty HF364/HF364N/HNF364SS-ID-600V-200A- HF364
Feature | HF364N (Fused + Neutral) | HNF364 (Non-Fused) | HF364 (Fused, 3-Wire) |
---|---|---|---|
Type | 3P + solid neutral fused | 3P non-fused | 3P fused (no neutral) |
Current/Voltage | 200A, 600V AC | 200A, 600V AC | 200A, 600V AC |
Fuse Support | Class J/R/T (3 fuses) | None | Class J/R/T (3 fuses) |
Wiring | 3P + neutral (4-wire) | 3P (3-wire) | 3P (3-wire) |
Short-Circuit Protection | 200kA (Class R/J) | Requires external OCPD | 200kA (Class R/J) |
Enclosure | NEMA Type 1 (indoor) | NEMA Type 1 (indoor) | NEMA Type 1 (indoor) |
Mechanism | Quick-make/break, visible blade | Quick-make/break, visible blade | Quick-make/break, visible blade |
Padlocking | Yes | Yes | Yes |
UL Service Entrance | Yes | No (disconnect only) | Yes |
Typical Use | 3-phase systems needing neutral | Motor disconnects | 3-phase circuits without neutral |
Neutral Presence
HF364N: Only model with a solid neutral (for 4-wire systems).
HNF364/HF364: 3-wire only (no neutral).
Fused vs. Non-Fused
HF364N & HF364: Include fuse protection (200kA fault rating with Class R/J).
HNF364: Disconnect-only (relies on upstream breakers/fuses).
Applications
HF364N: Service entrances, 3-phase + neutral loads (e.g., HVAC, industrial panels).
HF364: 3-phase circuits without neutral (e.g., motors, pumps).
HNF364: Simple isolation (maintenance, motor disconnects).